Find HiFlux filter solutions that fit your needs perfectly. Select one of the following industries to find a filter fit for your production
View our products, we have seperated them into categories so you can find what you’re looking for. You can also find filters made for your production in the Industries tab.
Find HiFlux filter solutions that fit your needs perfectly. Select one of the following industries to find a filter fit for your production
Find HiFlux filter solutions that fit your needs perfectly. Select one of the following industries to find a filter fit for your production
HiFlux Filtration A/S is a Danish company, specializing for more than 60 years in filtration solutions of liquids for the processing industry and the energy sector.
HiFlux Filtration A/S is a Danish company, specializing for more than 60 years in filtration solutions of liquids for the processing industry and the energy sector.
HiFlux Filtration A/S is a Danish company, specializing for more than 60 years in filtration solutions of liquids for the processing industry and the energy sector.
HiFlux / Solutions / Bag Filters and Magnetic Filters / Filter Unit TM16-P4x4250 HiFlux
HiFlux Magnetic/Bag Filter Units are used where there is a need for a complete solution for removal of magnetic particles and combine the advantages of magnetic and bag filtration.
HiFlux Units are used for partial flow filtration in district heating and cooling installations, as both magnetic and non-magnetic particles of less than 1 micron can be retained in the filter.
Partial flow filtration is used where there is a requirement for continuous flow, also during filter cleaning. Efficient removal of dirt and magnetic particles from the liquid reduces the number of breakdowns in the system and increases the life of measuring equipment, heat exchangers, pumps, valves and other components significantly.
In partial flow filtration 5-15% of the total flow is led out of the system and pumped through the magnetic/bag filter, and is then led back to the system – cleaned of sludge and magnetite. As the partial flow filter is not located in the main circuit, the flow through the filter can be interrupted and the filter cleaned without interrupting the main flow.
Continuous reduction of the sludge content reduces sedimentation in heat exchangers, pipes and other components, helping to keep heat transmission performance at a maximum and reducing corrosion in the system. Error indication in mechanical measuring equipment and errors in connection with inductive measuring are also minimised, which is why it is possible to achieve more reliable energy consumption measurements.
The magnetic bars in the filter are located in conducting pipes which lead the liquid through a magnetic field generated by magnets with changing polarity. This induces a field around even the smallest particles and so provides efficient retention of particles of less than 1 micron. The filter will actively retain ferromagnetic particles and some iron oxides of the Fe3O4, g-Fe2O4, d-Fe2O3type and other mixed oxides of Fe3O4, where the spinel structure FeO is substituted by other oxides, e.g. CoO, MnO, NiO, ZnO, Cr2O3.
Non-magnetic particles are retained efficiently in the filter bag. (See also data sheet for filter bags).
The HiFlux TM16-P4x4250 is designed as a complete unit for partial flow filtration in heating and cooling systems with a flow of 1000-3200 m³/h in the main line.
The filter unit accommodates current standards and norms for pressure vessels, complies with the EMC directive and is CE-labelled according to the Machinery Directive 2006/42/EC Annex II, A. The unit is supplied complete with pump and filter with a magnetic bag insert fitted compactly on a galvanized base frame.
The values and measurements shown are indicative. It is always the specific installation drawing and product specification that are applicable. For more specific dimensions of the filter, refer to the datasheets for Bag-Magnetic filters (e.g. TM16-P4250).
Drawings and values on datasheets are always indicative. It is the specific installation drawing and product specification that are valid.
Design pressure: | 10 bar or 16 |
Test pressure: | According to EN13445 |
Max. differential pressure: | 1,0 bar |
Filter area: | 17.000 cm² |
Max. working temperature: | 110° C (water) or according to customer re-quirements. |
Filter Volumen: | 220 liter |
Unit weight: | 550 kg |
Power supply: | 230V AC, 50 Hz or 3 x 400V AC, 50 Hz |
Flange connection: | DN80/100 PN16 EN1092-1 |
Filtration: | See also data sheet for filter bags |
Polypropylene: | 1-5-10-25-50-100-200 micron (max. 90°C) |
Polyester: | 1-5-10-50-75-100-150-200-300 micron (max. 150°C) |
140-160 m3/h depending on pump type and water column height.
The integral unit is fully tested and is quick and easy to install.
A differential pressure indicator can be fitted as an optional extra.
I would like to hear more
Choosing the right filters for your business requires specialized knowledge and our competent employees are ready to hear about your company’s needs, so that we can find the right solution together.
In some cases, the solution will be one of our many standard filters. In other cases, the filtering task requires us to customize the filters to meet the needs of your business. At HiFlux Filtration A/S’s technical department, engineers and technical developers with years of experience work on matching the right filters to the industry’s specific requirements.
If you want to get a quote for a filter you can fill our our inquiry form here.
Fields marked with * are required
"*" indicates required fields
Receive our latest news and stay updated. Make sure to read our privacy policy
© 2024 HiFlux Filtration A/S – Designet af Aveo web&marketing
We will setup contact between you and our partner. ‘
Fill out the form, and we will take care of the rest.