Find HiFlux filter solutions that fit your needs perfectly. Select one of the following industries to find a filter fit for your production
View our products, we have seperated them into categories so you can find what you’re looking for. You can also find filters made for your production in the Industries tab.
Find HiFlux filter solutions that fit your needs perfectly. Select one of the following industries to find a filter fit for your production
Find HiFlux filter solutions that fit your needs perfectly. Select one of the following industries to find a filter fit for your production
HiFlux Filtration A/S is a Danish company, specializing for more than 60 years in filtration solutions of liquids for the processing industry and the energy sector.
HiFlux Filtration A/S is a Danish company, specializing for more than 60 years in filtration solutions of liquids for the processing industry and the energy sector.
HiFlux Filtration A/S is a Danish company, specializing for more than 60 years in filtration solutions of liquids for the processing industry and the energy sector.
HiFlux Magnetic/Bag Filter Units are used where there is a need for a complete solution for removal of magnetic particles and combine the advantages of magnetic and bag filtration.
HiFlux Units are used for partial flow filtration in district heating and cooling installations, as both magnetic and non-magnetic particles of less than 1 micron can be retained in the filter.
Partial flow filtration is used where there is a requirement for continuous flow, also during filter cleaning. Efficient removal of dirt and magnetic particles from the liquid reduces the number of breakdowns in the system and increases the life of measuring equipment, heat exchangers, pumps, valves and other components significantly.
In partial flow filtration 5-15% of the total flow is led out of the system and pumped through the magnetic/bag filter, and is then led back to the system – cleaned of sludge and magnetite. As the partial flow filter is not located in the main circuit, the flow through the filter can be interrupted and the filter cleaned without interrupting the main flow.
Continuous reduction of the sludge content reduces sedimentation in heat exchangers, pipes and other components, helping to keep heat transmission performance at a maximum and reducing corrosion in the system. Error indication in mechanical measuring equipment and errors in connection with inductive measuring are also minimised, which is why it is possible to achieve more reliable energy consumption measurements.
The magnetic bars in the filter are located in conducting pipes which lead the liquid through a magnetic field generated by magnets with changing polarity. This induces a field around even the smallest particles and so provides efficient retention of particles of less than 1 micron. The filter will actively retain ferromagnetic particles and some iron oxides of the Fe3O4, g-Fe2O4, d-Fe2O3type and other mixed oxides of Fe3O4, where the spinel structure FeO is sub-stituted by other oxides, e.g. CoO, MnO, NiO, ZnO, Cr2O3.
Non-magnetic particles are retained efficiently in the filter bag. (See also data sheet for filter bags).
HiFlux Micro-line Wall Units are designed as complete units for partstream filtration in smaller heating and cooling systems with a flow of 10 -75 m3/h in the main line – or with a total system flow of up to 80 m3/h.
The filter unit accommodates current standards and norms for pressure vessels, and is CE-marked according to the Machinery Directive. The unit is supplied complete with pump and filter with a magnetic bag insert fitted compactly on a galvanised base frame as well as bracket for wall mounting.
Drawings and values on datasheets are always indicative. It is the specific installation drawing and product specification that are valid.
Design pressure: | 10 bar |
Test pressure: | 15 bar |
Max. differential pressure: | 1,0 bar |
Max. working temperature: | 110° C |
Filter Volumen: | 5 litres |
Unit weight: | 35 kg |
Connection: | G1″ ISO 228-1 |
G1 5/4″ ISO 228-1 | |
Filtration: | See also data sheet for filter bags |
Filter bag (PA): | 10-50 micron (max. 120 °C) |
Filter bag (PP): | 1-5-10-25-50-100 micron (max. 90 °C) |
The integrated unit is fully tested and is quick and easy to install.
A differential pressure indicator can be fitted as an optional extra (see data sheet for differential pressure indicator).
I would like to hear more
Choosing the right filters for your business requires specialized knowledge and our competent employees are ready to hear about your company’s needs, so that we can find the right solution together.
In some cases, the solution will be one of our many standard filters. In other cases, the filtering task requires us to customize the filters to meet the needs of your business. At HiFlux Filtration A/S’s technical department, engineers and technical developers with years of experience work on matching the right filters to the industry’s specific requirements.
If you want to get a quote for a filter you can fill our our inquiry form here.
Fields marked with * are required
"*" indicates required fields
Receive our latest news and stay updated. Make sure to read our privacy policy